APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10120 Issued:1992-01-29
Revised:2017-09-07
Style 10120 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Cable flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded FRPE or PE, 23 mils minimum average thickness, 20 mils minimum thickness at any point.
ShieldInner and outer shield are optional.
CoveringInner - (Optional) Extruded PVC, Nylon or Polyester, 2 mils minimum thickness, or lacquered braid. Outer -(Optional) Extruded PVC 15 mils minimum average thickness, 12 mils minimum thickness at any point.
BraidOptional.
JacketExtruded PVC
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring of electronic equipment.