APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10124 Issued:1992-03-12
Revised:2012-12-18
Style 10124 Single Conductor with Non-integral Jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG - 9 AWG tinned or bare, solid or stranded copper.
InsulationPVC, 30 mils min average, 27 mils minimum at any point.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Appliances (reinforced insulation).