Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Extruded PVC |
| 30-16 AWG conductor size | 18 mils min average | 16 mils minimum at any point |
| 15-10 AWG | 30 avg | 27 min |
| 9-8 AWG | 45 avg | 40 min |
| 7-2 AWG | 60 avg | 54 min |
| 1-4/0 AWG | 80 avg | 72 min |
|
Covering | Optional. A conductive coating maybe applied between the conductor and the insulation, thickness and material not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|