APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10158 Issued:1993-03-03
Revised:2011-11-10
Style 10158 Single-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame ( Use No. 1 ), Cable flame ( Use No. 2 ).
Conductor40 AWG min. Material not specified.
InsulationFor Use No. 1, material not specified. For Use No. 2, labeled or complies with manufacturer's Procedure having minimum ratings of 60 deg C and 30 Vac.
CoveringOptional. Extruded PVC, 13 mils min thickness at any point.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded PVC
Dia of cable under jacketMinimum averageMinimum at any point
0.250 inch or less15 mils12 mils
0.251-0.350 inch22 mils20 mils
0.351-0.424 inch30 mils27 mils
0.425-0.700 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseUse No. 1 - Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. Use No. 2 - Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.