Rating | 60 deg C, 30 Vac, Horizontal flame ( Use No. 1 ), Cable flame ( Use No. 2 ). |
|
Conductor | 40 AWG min. Material not specified. |
|
Insulation | For Use No. 1, material not specified. For Use No. 2, labeled or complies with manufacturer's Procedure having minimum ratings of 60 deg C and 30 Vac. |
|
Covering | Optional. Extruded PVC, 13 mils min thickness at any point. |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded PVC |
| Dia of cable under jacket | Minimum average | Minimum at any point |
| 0.250 inch or less | 15 mils | 12 mils |
| 0.251-0.350 inch | 22 mils | 20 mils |
| 0.351-0.424 inch | 30 mils | 27 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Use No. 1 - Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. Use No. 2 - Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. |
|