| Rating | 80, 90, 105 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 10 AWG, solid or stranded. |
|
| Insulation | Extuded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Assembly | Litz cable conductor consists of single strand magnet wire, R/C (OBMW2) magnet wire. Each single magnet wire strand is cabled together with the other magnet wire strands to form a conductor. AWG size to be determined by the DC Resistance Test per UL 1581. |
|
| Covering | Optional - Extruded PVC, 9 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring where not subjected to movement or mechanical abuse. Tag may also indicate the following: "600 Volts Peak for Electronic Use Only". |
|