APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10174 Issued:1993-06-22
Revised:2012-01-12
Style 10174 Single conducor cable using non-integral Jacket

Rating200 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of the style of the individual conductors used in making up the cable assembly shall be available.
ShieldOptional.
CoveringOptional. A barrier layer may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic tape wrap.
JacketFEP, dia. of cable 0.425 in. or less, 10 mils min average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or electronic equipment.