Style 10186 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min.
InsulationExtruded FEP, 2 mils minimum thickness at any point, 10 mils maximum thickness.
AssemblyInsulation may be applied directly over the conductor or applied as a spiral wrapped FEP thread (3 mils minimum thickness, 10 mils maximum thickness) and enclosed with "tubed on" insulation.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketExtruded FEP, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment or as insulated singles in jacketed multiconductor cables.