APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10219 Issued:1994-07-14
Revised:2012-03-30
Style 10219 Single or Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM.
AssemblyConsists of one insulated conductor and jacket. If signal wires are provided, they are twisted around main conductor. The lay is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Signal WireOptional - 5 V maximum, labeled or complying with Manufacturer's AWM Procedure
ShieldOptional.
CoveringOptional. Extruded PVC, 6 mils minimum thickness or PETP tape, 1 mil minimum thickness, may be applied over the conductor assembly.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseProbe Cable for use with instruments where shield (if provided) is grounded.