APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10220 Issued:1994-07-25
Revised:2012-03-21
Style 10220 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating150 deg C, 1000 Vdc, Horizontal flame.
Conductor28 AWG - 10 AWG, solid or stranded.
InsulationExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances (such as cold-cathode discharge tube leads for liquid crystal display equipment).

UL and the UL Logo are trademarks of UL LLC © 2024