Rating | 80 deg C, voltage not specified, Cable flame. |
|
Conductor | Inner - 30 AWG consisting of 7 strands of 0.10 mm, tinned or bare copper. Outer conductor - Braided copper tinned or bare, AWG not specified. |
|
Insulation | Inner - Extruded PE, 11 mils min average, 10 mils minimum at any point. Middle - Extruded PVC, 9 mils min average 7 mils min at any point. Outer - Extruded PVC, 9 mils min average 7 mils min at any point. |
|
Assembly | An inner conductor with inner insulation, optional inner shield, middle insulation, outer conductors, outer insulation, optional outer shield and overall jacket. |
|
Shield | Inner and outer shield are optional. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|