APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10269 Issued:1996-03-05
Revised:2014-10-10
Style 10269 Single conductor with extruded insulation.

Rating80, 90, 105 deg C, 1000 Vac or 1250 Vdc, Horizontal flame, Optional - Oil Resistant 60 deg C or 80 deg C.
Conductor30 AWG - 2000 kcmil, solid or stranded round.
InsulationPVC
30-9 AWG conductor size30 mils min average27 mils minimum at any point
8-7 AWG45 avg40 min
6-2 AWG60 avg54 min
1-4/0 AWG80 avg72 min
250-500 kcmil95 avg86 min
550-1000 kcmil110 avg99 min
1100-2000 kcmil125 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances; or Internal Wiring of Appliances where exposed to oil at a temperature not exceeding 60 deg. C or 80 deg. C (whichever is applicable). Tags may also indicate the following: 3,500 V peak - for electronic use only.

UL and the UL Logo are trademarks of UL LLC © 2024