APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10276 Issued:1996-04-10
Revised:2012-07-25
Style 10276 Single Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating80 deg C, 300 Vac, 600 Vac, Horizontal flame.
Conductor18 AWG - 2 AWG solid or stranded round.
InsulationExtruded PVC
18-11 AWG conductor size11 mils min average10 mils minimum at any point
10-9 AWG20 avg18 min
8-5 AWG30 avg27 min
4-2 AWG40 avg36 min
JacketExtruded Polyamide
18-9 AWG4 mils min at any point
8-5 AWG5 min
4-2 AWG6 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing in Cables for Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024