APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10304 Issued:1997-03-04
Revised:2011-12-02
Style 10304 Multiple-conductor cable with non-integral jacket

Rating200 deg C, 150 Vac, 30 Vac, 60 Vac, 90 Vac, Horizontal flame.
Conductor44 AWG min, material not specified.
InsulationFEP or PFA or PTFE, TFE, 8 mils min at any point, 125 mils max.
AssemblyInsulated conductor with optional inner shield, optional covering, optional outer shield and jacket.
ShieldInner and outer shield are optional.
CoveringOptional. PFA, 8 mils min at any point, 125 mils max.
JacketFEP or PFA or PTFE, TFE, 8 mils min at any point, 125 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 Circuits of Electronic Equipment.