Rating | 125 deg C, 150 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 6 AWG solid or stranded, solid magnet or litz cable magnet wire, R/C (OBNW2) magnet wire rated at min 125 deg. C. Each single magnet wire strand is cabled together with other magnet wire strands to form a conductor. AWG size to be determined by the DC Resistance Test in the Standard for Wire and Cable Test Methods, UL 2556. |
|
Insulation | Extruded ETFE |
| AWG Conductor Size¿ | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 40-20 | 5.5 | 5 |
| 19-15 | 8 | 7 |
| 14-10 | 13 | 12 |
| 9-6 | 20 | 18 |
| Tinned copper may be employed with ETFE insulation. ETFE may be extruded in two or three layers. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, such as electronic computers and business machines, where not subject to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following: "300 Volts peak for electronic use only". |
|