Rating | 125 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 6 AWG solid or stranded, solid magnet, litz cable magnet wire or R/C (OBMW2) magnet wire with AWG size to be determined by the Resistance Test. And tinned copper. |
|
Insulation | Extruded ETFE |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 40-20 AWG | 5.5 mils | 5 mils |
| 19-15 AWG | 8 mils | 7 mils |
| 14-10 AWG | 13 mils | 12 mils |
| 9-6 AWG | 20 mils | 18 mils |
| May be in two or three layers. |
|
Assembly | Each single magnet wire strand is cabled together with other magnet wire strands to form a conductor. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General.
Optional - Tags may indicate the following: "600 Volts peak for electronic use only". |
|
Use | Internal wiring of electronic equipment, such as electronic computers and business machines, where not subject to movement or mechanical damage.
May also be used for further processing in cables and lead wire for UL 1950 applications. |
|