Rating | 125 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 6 AWG solid or stranded, Solid magnet or Litz cable magnet wire, R/C (OBMW2) magnet wire rated at min 125 deg C. Each single magnet wire strand is cabled together with other magnet wire strands to form a conductor. AWG size to be determined by the Resistance Test Per UL 1581. In addition, tinned copper may be employed when ETFE insulation is used. May extrude ETFE in two or three layers. |
|
Insulation | ETFE |
| 40-20 AWG conductor size | 9 mils min average | 8 mils min at any point |
| 19-15 AWG | 10 avg | 9 min |
| 14-10 AWG | 13 avg | 12 min |
| 9-6 AWG | 20 avg | 18 min |
| Tinned copper may be employed when ETFE insulation is used. May extrude ETFE in two or three layers. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, such as electronic computers and business machines, where not subject to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following:"2500 Volts peak for electronic use only". |
|