APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10316 Issued:1997-09-10
Revised:2011-12-22
Style 10316 Single or multiple conductor with extruded insualtion

Rating125 deg C, 600 Vac, Horizontal flame.
Conductor40 AWG - 6 AWG solid or stranded, Solid magnet or Litz cable magnet wire, R/C (OBMW2) magnet wire rated at min 125 deg C. Each single magnet wire strand is cabled together with other magnet wire strands to form a conductor. AWG size to be determined by the Resistance Test Per UL 1581. In addition, tinned copper may be employed when ETFE insulation is used. May extrude ETFE in two or three layers.
InsulationETFE
40-20 AWG conductor size9 mils min average8 mils min at any point
19-15 AWG10 avg9 min
14-10 AWG13 avg12 min
9-6 AWG20 avg18 min
Tinned copper may be employed when ETFE insulation is used. May extrude ETFE in two or three layers.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, such as electronic computers and business machines, where not subject to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following:"2500 Volts peak for electronic use only".

UL and the UL Logo are trademarks of UL LLC © 2024