Rating | 90 deg C, 1000 Vac and/or 1200 Vdc, Horizontal flame. Optional - 60 deg C or 80 deg C Oil. |
|
Conductor | 30 AWG - 2000 kcmil, solid or stranded. |
|
Insulation | Extruded PVC. |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 30-9 AWG | 30 mils | 27 mils |
| 8 AWG | 45 mils | 40 mils |
| 7-2 AWG | 60 mils | 54 mils |
| 1-4/0 AWG | 80 mils | 72 mils |
| 250-500 kcmil | 95 mils | 86 mils |
| 550-1000 kcmil | 110 mils | 99 mils |
| 1100-2000 kcmil | 125 mils | 112 mils |
|
Covering | Optional. Extruded PVC, 5 mils minimum thickness at any point, 40 mils maximum thickness. |
|
Shield | Optional. |
|
Jacket | Optional. Extruded PVC, 30 mils minimum average thickness, 23 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Appliances. Tags may also indicate the following: 3500 V peak - for electronic use only. |
|