APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1035 Issued:1959-05-01
Revised:2012-04-11
Style 1035 Single Conductor with extruded insulation

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor22 AWG - 18 AWG consisting of 30 AWG strands.
InsulationExtruded PE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils mininum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph and Volume Control Use where Insulation is exposed to a temperature not exceeding 60 deg C and the jacket is exposed to a temperature not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024