Rating | 90 deg C, 125 Vac, Horizontal flame. |
|
Conductor | Conductor - Copper, nickel-alloy, or stainless steel conductor, 39 - 31 AWG, wound 10 turns per inch min, 70 turns per inch max, on a core of Acrylic, Fiberglass, Polyester or Rayon. Core may be coated with Silicone Rubber.
Sensor Wire - Copper, nickel-alloy, or stainless steel conductor, 40 - 35 AWG, wound 10 turns per inch min, 70 turns per inch max. |
|
Covering | Provided over conductor. Extruded PVC or extruded PE, 20 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
Insulation | Extruded PVC, 18 mils minimum average thickness, 15 mils minimum thickness at any point. |
|
Assembly | Conductor enclosed by Covering. Sensor Wire provided over the Covering. Insulation provided over the Sensor Wire. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of heated pads where the acceptability of the combination has been determined by Underwriters Laboratories Inc. |
|