APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10376 Issued:1998-11-02
Revised:2012-11-23
Style 10376 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor38 AWG minimum. Solid or stranded.
InsulationExtruded Foamed PE, 37 mils minimum average thickness, 30 mils minimum thickness at any point.
JacketExtruded PVC, 24 mils minimum average thickness, 20 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.