APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10396 Issued:1999-01-26
Revised:2011-11-03
Style 10396 Multiconductor cable with extruded non-integral jacket.

Rating105 deg C, 300 Vac, Cable flame.
Conductor40 AWG minimum. solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional. Extruded PVC, 6 mils or heavier thickness, may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC
Diameter of core assembly under jacket*Minimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.501 inch80 mils64 mils
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or extrunal wire. Tags may also indicate the following: "600 Volts peak for Electronic Use Only."

UL and the UL Logo are trademarks of UL LLC © 2024