APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10397 Issued:1999-01-26
Revised:2019-11-07
Style 10397 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor40 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC
major dia in inches
0.425 or less45 mils min average36 mils minimum at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia8O avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024