APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10425 Issued:1999-06-24
Revised:2012-03-16
Style 10425 Single-Conductor Cable Using Extruded Non-Integral Jacket and Covering

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG solid or stranded round, tinned or bare.
InsulationExtruded Solid or cellular FRPE
AWG Conductor Size¿Minimum average thickness (mils)Minimum thickness at any point (mils)
30-161513
15-102018
Barrier TapeOptional Polyester tape.
AssemblyInsulated conductor with optional barrier tape, optional inner shield, optional inner covering, optional outer shield, jacket and outer covering.
ShieldInner and outer shield are Optional.
Covering(Optional) Inner - A textile braid, nylon jacket (2 mils minimum covering thickness), or 8 mils minimum thickness of semi-rigid or regular PVC may be applied between the insulation and shield. (Required) Outer - Nylon - 2 mils minimum thickness at any point.
JacketPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.