| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 10 AWG solid or stranded round, tinned or bare. |
|
| Insulation | Extruded Solid or cellular FRPE |
| AWG Conductor Size¿ | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 30-16 | 15 | 13 |
| 15-10 | 20 | 18 |
|
| Barrier Tape | Optional Polyester tape. |
|
| Assembly | Insulated conductor with optional barrier tape, optional inner shield, optional inner covering, optional outer shield, jacket and outer covering. |
|
| Shield | Inner and outer shield are Optional. |
|
| Covering | (Optional) Inner - A textile braid, nylon jacket (2 mils minimum covering thickness), or 8 mils minimum thickness of semi-rigid or regular PVC may be applied between the insulation and shield. (Required) Outer - Nylon - 2 mils minimum thickness at any point. |
|
| Jacket | PVC, 15 mils min average, 12 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment. |
|