APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1043 Issued:1959-05-01
Revised:2012-03-30
Style 1043 Single conductor with extruded insulation

Rating80 deg C, 300 Vac, Horizontal flame. Optional - 60 or 80 deg C Oil.
Conductor20 AWG - 16 AWG Solid or Stranded. No. 18-16 AWG. shall be stranded. All stranded conductors shall consist of No. 30 AWG. or smaller strands.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 80 deg C; or Internal Wiring of Lighting Equipment where exposed to temperatures not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable.)