APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10438 Issued:1999-07-12
Revised:2011-12-01
Style 10438 Single conductor with extruded insulation.

Rating75 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG - 1000 kcmil, solid or stranded.
InsulationExtruded PVC.
36-12 AWG conductor size15 mils minimum average thickness13 mils minimum thickness at any point
11-9 AWG20 avg18 min
8-4 AWG30 avg27 min
3-2 AWG39 avg35 min
1-4/0 AWG47 avg42 min
213-500 kcmil60 avg54 min
501-1000 kcmil70 avg63 min
CoveringOptional. A conductive coating maybe applied between the conductor and the insulation, thickness and material not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing into cables.

UL and the UL Logo are trademarks of UL LLC © 2024