Revised:2012-06-04
Style 10448 Single conductor cable using non-integral jacket

Rating150 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum.
InsulationExtruded XLFRPE or extruded XLPE, solid or cellular, 4 mils minimum at any point, 100 mils maximum.
AssemblyInsulated conductor with optional inner covering, jacket, optional shield and optional outer covering.
ShieldOptional.
CoveringInner - (Optional)Over any or all singles - 2 mils minimum at any point extruded XLPE. Outer - (Optional)XLPE, Class 43, 5 mils minimum at any point.
JacketXLPE, 5 mils min average, 3 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances or Electronic Equipment