APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10453 Issued:1999-10-13
Revised:2012-07-23
Style 10453 Single Conductor using Non-Integral Extruded Jacket

Rating60 or 80 or 90 or 105 deg C, 30 Vac, Horizontal Flame.
Conductor28 AWG - 12 AWG, Solid or Stranded Round.
InsulationExtruded PVC, 5 mils minimum average, 4 mils minimum at any point.
AssemblyCore may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional - One or more.
CoveringOptional - Extruded PVC, 7 mils minimum average, 6 mils minimum at any point.
JacketExtruded PVC, 15 mils minimum average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024