APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10457 Issued:1999-11-12
Revised:2012-07-26
Style 10457 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 300 Vac.
Conductor20 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationFEP, 11 mils min average, 10 mils minimum at any point.
ShieldOptional.
JacketPVC, 18 mils min average, 14 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseNonheating Leads for heater mats, factory assembled where the acceptability of the combination is to be determined by Underwriters Laboratories.

UL and the UL Logo are trademarks of UL LLC © 2024