APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1046 Issued:1959-05-01
Revised:2011-07-28
Style 1046 Single Conductor with Extruded Insulation.

Rating90 deg C, 300 Vac, Horizontal flame, Optional - 60 or 80 deg C Oil Resistant.
Conductor20 AWG - 16 AWG Solid or Stranded round. 18 AWG - 16 AWG shall be stranded. All stranded conductors shall consist of No. 30 AWG. or smaller strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
CoveringExtruded nylon, 2 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 90 deg C; or Internal Wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 90 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable).

UL and the UL Logo are trademarks of UL LLC © 2024