APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10497 Issued:2000-05-29
Revised:2011-08-04
Style 10497 Single Conductor with Extruded Non-Integral Jacket

Rating150 deg C, 300 Vac, Horizontal flame, Optional - 80 deg C Oil
InsulationLabeled or complying with manufacturer's AWM Procedure
AssemblyIndividually insulated conductors. Insulated conductor with optional inner shield, option inner covering, optional outer shield and jacket. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
BarrierOptional - May be a fibrous wrap serving, or braid; paper; nylon; oriented PETP; or thermoplastic-tape wrap
ShieldOptional
CoveringOptional - Extruded FEP, 6 mils minimum thickness at any point
JacketExtruded FEP
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less25 mils20 mils
0.426-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
2.501 inch and larger80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseExternal interconnection or internal wiring of appliances or electronic equipment. Tags may indicate the following: 600 V peak - For Electronic Use Only

UL and the UL Logo are trademarks of UL LLC © 2024