Rating | 80 deg C, 300 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil. |
|
Conductor | 20 AWG - 16 AWG Solid or Stranded Round. No. 20 AWG shall be solid or stranded. No. 18-16 AWG shall be stranded. All stranded conductors shall consist of No. 30 AWG or smaller strand. |
|
Insulation | Extruded PVC, 45 mils min average, 40 mils minimum at any point. |
|
Covering | Extruded nylon in 2-mil minimum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | (a) Internal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C; or (b) internal wiring of gas or oil-fired domestic heating equipment where exposed to temperatures not exceeding 80 deg C; or (c) internal wiring of lighting circuits in refrigerating equipment where exposed to temperatures not exceeding 80 deg C. |
|