Style 1050 Single conductor with extruded insulation

Rating80 deg C, 300 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil.
Conductor20 AWG - 16 AWG Solid or Stranded Round. No. 20 AWG shall be solid or stranded. No. 18-16 AWG shall be stranded. All stranded conductors shall consist of No. 30 AWG or smaller strand.
InsulationExtruded PVC, 45 mils min average, 40 mils minimum at any point.
CoveringExtruded nylon in 2-mil minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
Use(a) Internal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C; or (b) internal wiring of gas or oil-fired domestic heating equipment where exposed to temperatures not exceeding 80 deg C; or (c) internal wiring of lighting circuits in refrigerating equipment where exposed to temperatures not exceeding 80 deg C.