APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10508 Issued:2000-08-08
Revised:2011-10-11
Style 10508 Single conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame, internal use; Cable flame, external use.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
CoveringOptional. A 10 mils or heavier THV covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded THV - See Facing Page for Compound Designation
@ Dia. of Cable under Jacket in inchesMin averageMin at any point
0.700 or lessinternal use10 avg8 min
0.700 or lessexternal use30 avg24 min
0.701 - 1.000 diainternal use10 avg8 min
0.701 - 1.000 diaexternal use45 avg36 min
1.001 - 1.500 diainternal use10 avg8 min
1.001 - 1.500 diaexternal use60 avg48 min
@ Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024