APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10509 Issued:2000-08-08
Revised:2011-11-10
Style 10509 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame, internal use; Cable flame, external use.
InsulationLabeled or complying with manufacturer's AWM Procedure.
CoveringOptional. A 10 mils or heavier THV covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded THV.
Internal UseExternal Use
*Diameter of core assembly under jacketMinimum average thicknessMinimum thicknes ar any pointMinimum average thicknessMinimum thicknes ar any point
0.700 inch or less10 mils8 mils30 mils24 mils
0.701-1.000 inch10 mils8 mils45 mils36 mils
1.001-1.500 inch10 mils8 mils60 mils48 mils
* Major diamter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.