APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10524 Issued:2000-10-30
Revised:2012-04-12
Style 10524 Single conductor with extruded insulation

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32 - 14 AWG, tinned or bare copper.
InsulationPVC.
AWGMinimum average thickness(mils)Minimum thickness at any point(mils)
32 - 151513
142018
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs insulated singles in external interconnection cable for electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024