APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10544 Issued:2001-02-28
Revised:2011-10-03
Style 10544 Single insulation with extruded Non-integral Jacket

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded.
InsulationExtruded PE or FRPE, 23 mils min average, 21 mils minimum at any point.
AssemblyInsulated conductor with optional covering, optional inner shield, inner jacket, optional outer shield and optional outer jacket.
CoveringOptional. PVC, Nylon (Polyamide), or Polyester, 2 mils minimum, or lacquered braid.
ShieldOptional inner.
JacketInner - TPE , 15 mils min average, 12 mils minimum at any point.
ShieldOptional outer
JacketOptional outer- Extruded TPE, 15 mils minimum average, 12 mils minimum at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring