APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10545 Issued:2001-03-29
Revised:2019-11-07
Style 10545 Single conductor cable using non-integral jacket.

Rating80 deg C, voltage rating not specified, Cable flame.
Conductor36 AWG min., solid or stranded round, tinned or bare copper.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyFillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the individual conductor.
ShieldOptional.
CoveringOptional. A 4 mil or heavier wall of thermoplastic covering may be extruded over the conductor with or without shields).
JacketPUR
dia in inches
0.425 or less45 mils min average36 mils minimum at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dai and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection.

UL and the UL Logo are trademarks of UL LLC © 2024