Rating | 80 deg C, 1000 Vac or 1200 Vdc. |
|
Conductor | 30 AWG - 3/0 AWG solid or stranded round. |
|
Insulation | Extruded FRPP or extruded PP |
| Conductor size AWG | Minimum average thickness | Minimum thickness at any point |
| 30-16 | 15 mils | 13 mils |
| 15-9 | 20 mils | 18 mils |
| 8-7 | 30 mils | 27 mils |
| 6-2 | 45 mils | 40 mils |
| 1-3/0 | 60 mils | 54 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For further processing in Cables for Electronic Equipment or Appliances. |
|