APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10550 Issued:2001-04-24
Revised:2011-10-14
Style 10550 Single Conductor with Extruded Insulation.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor33 AWG - 10 AWG Silver/Copper Alloy, Tin, or Tin-Plated Alloy.
InsulationETFE or FEP or PFA
19-15 AWG conductor size9 mils min average8 mils min at any point
14-10 AWG15 avg13 min
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketPUR/PVC blend
0.350 inches or lessd20 mils min average16 mils minimum at any point
0.351-0.70030 avg24 min
0.701-1.00045 avg36 min
1.001-1.50060 avg48 min
1.501-2.50080 avg64 min
2.501-4.000110 avg88 min
4.001 or larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2025