APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1056 Issued:1959-05-01
Revised:2013-11-22
Style 1056 Single conductor with extruded insulation

Rating105 deg C, 600 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil.
Conductor20 AWG - 10 AWG, stranded.
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Indoor or Outdoor Refrigerating Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024