APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10578 Issued:2001-08-13
Revised:2011-07-28
Style 10578 Single conductor with extruded insulation.

Rating80 deg C, 300 Vac.
Conductor30 AWG - 10 AWG solid or stranded round.
InsulationExtruded PE, extruded foamed PE, extruded FRPE or extruded foamed FRPE
Conductor size AWGMinimum average thicknessMinimum thickness at any point
30-1615 mils13 mils
15-1020 mils18 mils
Barrier LayerOptional - Polyester tape over conductor.
AssemblyInsulated conductor with optional barrier tape, optional inner shield, optional inner covering, optional middle shield, optional outer covering and optional outer shield.
ShieldOptional
CoveringInner: Optional - A textile braid; extruded nylon jacket, 2 mil minimum thickness; or extruded PVC, 8 mils minimum thickness; or extruded SRPVC, 8 mils minimum thickness; may be applied between the insulation and shield.
ShieldOptional
CoveringOuter: Optional - Extruded PVC, PI, Polyester, PE, FRPE, PP or EFTE, 2 mils minimum thickness, or a lacquered braid.
ShieldOptional
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing.

UL and the UL Logo are trademarks of UL LLC © 2024