APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10587 Issued:2001-10-23
Revised:2019-11-07
Style 10587 Single conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 600, 1000 Vac, Cable flame.
Conductor32 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
ShieldOptional.
CoveringOptional. 4 mil or heavier wall of PVC or other thermoplastic covering may be extruded over the conductor assembly or groups of conductors (with or without shields).
JacketExtruded TPU
major dia in inches
0.700 or less45 mils min average36 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.500 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024