APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10593 Issued:2001-11-09
Revised:2011-09-26
Style 10593 Single Conductor Cable With Non-Integral Jacket

Rating80 deg C, 600 Vac, Cable flame.
Conductor30 AWG - 500 kcmil.
InsulationLabeled or complying with the manufacturer's AWM procedure or extruded PVC
Conductor sizeMinimum average thicknessMinimum thickness at any point
30-16 AWG20 mils18 mils
14-10 AWG32 mils28 mils
8-4 AWG46 mils40 mils
2-3/0 AWG56 mils50 mils
4/0-300 kcmil70 mils62 mils
350-500 kcmil86 mils76 mils
ShieldOptional.
JacketExtruded PUR
Diameter of under jacketMinimum average thicknessMinimum thickness at any point
0.700 inches or less45 mils36 mils
0.701-1.000 inches60 mils48 mils
1.001-1.500 inches80 mils64 mils
1.501-2.500 inches110 mils88 mils
2.500 inches and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or Internal Wiring of Electronic Equipment.