Rating | 150 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 36 AWG min, solid or stranded round. |
|
Insulation | Extruded solid or foam ETFE or FEP or MFA or PFA or PTFE or non-extruded PTFE tape, 5 mils min at any point, 75 mils max. |
|
Assembly | Insulated conductor with optional inner shield, optional inner covering, optional outer shield and optional outer covering. |
|
Shield | Optional - Inner. |
|
Covering | Inner - (Optional)Extruded Solid or Cellular PFA, MFA, FEP, ETFE or PTFE (PTFE may be tape wrapped). Thicknesses not specified. Outer - (optional)same as inner. |
|
Shield | Optional - Outer. |
|
Covering | Outer - (Optional) Extruded solid or foam ETFE or FEP or MFA or PFA or PTFE or non-extruded PTFE tape, thicknesses not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|