APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10598 Issued:2001-12-12
Revised:2011-10-03
Style 10598 Single insulation with extruded Non-integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round.
InsulationExtruded PE, 15 mils min average, 13 mils minimum at any point.
AssemblyInsulated conductor with optional covering, inner shield, inner jacket, optional outer shield and optional outer jacket.
CoveringOptional. Rayon braid between insulation and shield.
ShieldInner - Required.
JacketInner - FRPE, 15 mils min average, 12 mils minimum at any point.
ShieldOuter - optional.
JacketOuter - (optional) FRPE, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring