APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10600 Issued:2002-01-22
Revised:2011-10-19
Style 10600 Single-conductor cable using non-integral jacket.

Rating80 deg C, 120 Vac, 240 Vac, 300 Vac, Cable flame, 75 deg C wet.
Conductor20 AWG - 14 AWG, stranded.
Conductive CoreOver the conductor is an extruded carbon-loaded (radiation cross-linked) polyolefin, thickness not specified.
BraidNickel-Copper 90% coverage.
CoveringOptional. modified polyurethane, polyester or thermoplastic elastomer, 12 mils minimum at any point.
InsulationExtruded HDPE, 18 mils minimum average, 16 mils minimum at any point.
ShieldTinned or Nickel-Copper 85% coverage.
JacketExtruded ETFE or TPE, 13 mils minimum average, 11 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe-Heating Conductor.

UL and the UL Logo are trademarks of UL LLC © 2024