APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10614 Issued:2002-04-26
Revised:2011-11-10
Style 10614 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded TPU/PVC blend.
*Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.501 inch80 mils64 mils
* Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024