Rating | 80 deg C, 600 Vac. |
|
Conductor | 26 AWG - 3/0 AWG, solid or stranded, tinned or bare copper. |
|
Insulation | FRPE |
| 26-22 AWG conductor size | 12 mils min average | 11 mils minimum at any point |
| 21-16 AWG | 15 avg | 13 min |
| 15-12 AWG | 20 avg | 18 min |
| 11-9 AWG | 24 avg | 22 min |
| 8-5 AWG | 28 avg | 25 min |
| 4-2 AWG | 30 avg | 27 min |
| 1-2/0 AWG | 40 avg | 36 min |
| 3/0-4/0 AWG | 48 avg | 43 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For further processing into cables only. |
|