APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10618 Issued:2002-05-02
Revised:2011-10-10
Style 10618 Single conductor cable using extruded non-integral jacket.

Rating150 deg C, 600 Vac, Horozontal flame, Cable flame.
Conductor40 AWG minimum.
InsulationLabeled or complying with AWM Procedure.
AssemblyInsulated conductor with optional filler, optional tape, optional covering, optional shield and jacket.
FillersOptional. Single or mixed of ETFE, PFA, FEP, or Cellular PTFE.
BinderOptional. ETFE, PFA, FEP, or Cellular PTFE tape over fillers.
CoveringOptional. Extruded PFA or extruded FEP, 10 mils minimum thickness, or extruded ETFE, 15 mils minimum thickness.
ShieldOptional.
JacketExtruded FEP.
Diameter of cable under jacketMinimum averageMinimum at any point
0.350 inch or less10 mils8 mils
0.351-0.500 inch13 mils10 mils
0.501-0.700 inch15 mils12 mils
0.701-1.500 inch20 mils16 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.