APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1062 Issued:1959-05-01
Revised:2012-03-09
Style 1062 Single conductor with extruded insulation

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor20 AWG-18 AWG, solid or stranded. Stranding shall consist of 30 AWG or smaller strands.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
ShieldOptional.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or electronic equipment.