APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10622 Issued:2002-05-31
Revised:2011-09-13
Style 10622 Single Conductor Cable with Extruded Non-Integral Jacket

Rating250 deg C, 150 Vac, Horizontal flame.
Conductor44 AWG - 10 AWG solid or stranded round.
InsulationPFA or PTFE - thickness per table below
44-20 AWG conductor size6 mils min average5 mils min at any point
19-15 AWG9 avg8 min
14-1012 avg11 min
AssemblyInsulated conductor with optional inner covering, optional inner shield, optional middle covering, optional outer shield and optional outer covering.
ShieldInner and outer shield are optional.
CoveringInner, middle and outer - (Optional) PFA or PTFE. Thicknesses not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024